SparkQuote NEC calculators
NEC 2023 electrical calculators: wire size, ampacity, voltage drop, conduit fill, box fill, load.
| Endpoint | https://sparkquote.ai/mcp (streamable-http) |
|---|---|
| Registry version | 1.0.1 |
| Now | 10 tools · grade A (96) · pin ts_cf7aa2773333d530029abc8b7a87df15 · protocol 2025-06-18 |
| First / last listed | 2026-10-26 00:08 UTC / 2026-10-26 00:08 UTC |
| Grade over time | 2026-10-26: A (96), 10 tools |
Is this your server? Own a server? ToolFit hosted watch re-checks it every 24 h ($0.25 per 30 days) or 6 h ($0.60) and sends you an HMAC-signed webhook when its tools or grade change: POST https://api.youraitools.co/toolfit/v1/watch. To opt out, see About & opt-out.
Tools: wire_size voltage_drop watts_to_amps conduit_fill box_fill load_calculator ohms_law panel_schedule bid_calculator nec_ampacity
wire_size | Minimum conductor size for a circuit: NEC Table 310.16 ampacity at the termination temperature rating, the 240.4(D) small-conductor limits, voltage drop over the run, and the Table 250.122 equipment grounding conductor, increased in proportion under 250.122(B) when voltage drop upsizes the conductors. params: material*, temp*, amps*, volts*, phase*, feet*, limit* |
voltage_drop | Voltage drop for a given conductor size, current and one-way length, single- or three-phase, from NEC Chapter 9 Table 8 circular mils (VD = 2·K·I·L / CM, or √3 for three-phase). params: material*, awg*, amps*, volts*, phase*, feet* |
watts_to_amps | Current drawn by a load in watts at a voltage and power factor, single- or three-phase, plus the 125% continuous-load value. params: watts*, volts*, phase*, pf* |
conduit_fill | Percent fill and maximum number of THHN/THWN-2 conductors of one size in EMT or PVC Schedule 40, from NEC Chapter 9 Tables 1, 4 and 5. params: type*, size*, awg*, count* |
box_fill | Minimum outlet box volume from NEC 314.16(B): conductor, device (2 each), clamp and grounding allowances times the Table 314.16(B) volume for the largest conductor. params: awg*, conductors*, devices*, clamps*, grounds* |
load_calculator | Dwelling service load by the NEC 220.82 optional method: 3 VA/ft² lighting, small-appliance and laundry circuits, fixed appliances, demand factor, heating or cooling, and the minimum standard service size. Leave an appliance out to count it as 0 VA. params: sqft*, small*, laundry*, range, dryer, heater, dishwasher, disposal, ev, other, hvac |
ohms_law | Ohm's law and power: give exactly two of voltage, current, resistance and power; the other two are calculated. params: v, i, r, p |
panel_schedule | Lays circuits out on a 120/240 V single-phase or 208Y/120 V three-phase panel and totals the load per phase with the imbalance. params: system*, spaces*, circuits* |
bid_calculator | Electrical bid price from materials, markup, labor hours and rate, job costs, overhead and a target net margin (price = break-even / (1 − margin)). params: materials*, markup, hours*, rate*, direct, overhead*, margin* |
nec_ampacity | Allowable ampacity of one insulated conductor from NEC Table 310.16 (not more than three current-carrying conductors in a raceway or cable, 30°C ambient), before any adjustment or correction factors and before the 240.4(D) small-conductor limits. params: material*, temp*, size* |
Entries describe changes in tool definitions. They are not statements about a server, its quality or its author. The grade measures how the tool definitions fit model providers (token cost, schema compatibility, confusable names) as scored by the ToolFit engine at the time of the listing. JSON: append .json. Opt-out: how or hello@youraitools.co.