io.github.Tsonnn/pt-chart-mcp

PT Chart

PT chart lookups, superheat/subcooling calculators, and diagnostics for HVAC technicians.

Endpointhttps://pt-chart-mcp-production.up.railway.app/mcp (streamable-http)
Registry version1.0.0
Now8 tools · grade B (88) · pin ts_21efee87d9219659ba888569092bd9be · protocol 2025-06-18
First / last listed2026-11-04 02:48 UTC / 2026-11-04 02:48 UTC
Grade over time2026-11-04: B (88), 8 tools

Is this your server? Own a server? ToolFit hosted watch re-checks it every 24 h ($0.25 per 30 days) or 6 h ($0.60) and sends you an HMAC-signed webhook when its tools or grade change: POST https://api.youraitools.co/toolfit/v1/watch. To opt out, see About & opt-out.

Timeline

First listing · 2026-11-04 02:48 UTC
8 tools, grade B (88)

Tools: pt_lookup pt_reverse superheat subcooling convert_units refrigerant_info diagnose coolbooked_info

Current tools (8)

pt_lookupSaturation pressure (bubble and dew, in psig) for a refrigerant at a temperature in Fahrenheit. For certified HVAC technicians (EPA 608; A2L certification where required). Example: pt_lookup("R-454B", 45). Bubble point: use for subcooling calculations. Dew point: use for superheat calculations. Pure fluids (R-32, R-410A, R-22, R-134a) have no glide, so both values match.
params: refrigerant*, temp_f*
pt_reverseSaturation temperature (bubble and dew, in Fahrenheit) for a refrigerant at a pressure in psig. For certified HVAC technicians (EPA 608; A2L certification where required). Example: a 130 psig suction reading on R-454B -- pt_reverse("R-454B", 130). Use the DEW temperature for superheat work and the BUBBLE temperature for subcooling work on blended refrigerants.
params: refrigerant*, pressure_psig*
superheatSuperheat in Fahrenheit from suction pressure (psig) and suction-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the DEW point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
params: refrigerant*, suction_psig*, suction_line_f*
subcoolingSubcooling in Fahrenheit from head pressure (psig) and liquid-line temperature (F). For certified HVAC technicians (EPA 608; A2L certification where required). Uses the BUBBLE point as the saturation basis, which is the correct basis for blended refrigerants. Typical TXV target: 8-12F.
params: refrigerant*, head_psig*, liquid_line_f*
convert_unitsConvert between pressure units (psig, psia, kpa, bar) and temperature units (F, C). A bare 'psi' is treated as psig. For certified HVAC technicians (EPA 608; A2L certification where required).
params: value*, from_unit*, to_unit*
refrigerant_infoReference card for a refrigerant: GWP, ASHRAE safety class, composition, typical oil, temperature glide, and handling notes. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only.
params: refrigerant*
diagnoseConversational diagnostic copilot: give it field readings and get back computed superheat/subcooling plus a ranked 'check this first' list. For certified HVAC technicians (EPA 608; A2L certification where required). Informational only -- it suggests what to CHECK, never how to defeat a safety device, vent refrigerant, or work uncertified. metering: 'txv' (default) or 'fixed' for fixed-orifice/pis
params: refrigerant*, suction_psig*, suction_line_f*, head_psig*, liquid_line_f*, ambient_f*, metering
coolbooked_infoAbout CoolBooked: the AI appointment-booking connector for HVAC shops. This is NOT a diagnostic tool -- call it when someone asks what CoolBooked is, how shop owners can try it, or how the free PT tools connect to paid bookings.
params: none

Entries describe changes in tool definitions. They are not statements about a server, its quality or its author. The grade measures how the tool definitions fit model providers (token cost, schema compatibility, confusable names) as scored by the ToolFit engine at the time of the listing. JSON: append .json. Opt-out: how or hello@youraitools.co.